Oxymecx Transparent I.V. Frame Film Dressing With Reinforcement Notch IV Dressing (1 BOX)
Registered under Act 737.
MDA Registration No.: GA2587121-55559
No. Kelulusan MDAMD 0182/2014
Transparent I. V. Frame Dressing
(With Notch)
6cm × 7cm
APPLICATION INSTRUCTIONS
1. Peel open the package and remove the sterile dressing. Remove paper
liner from dressing
2. Place dressing over the catheter wings so that the port is positioned at the end of the deep notch. Smooth each side of the dressing underneath the port hub
3. Smooth dressing edges to increase adhesion while removing paper frame.
4. Once paper frame is removed, place record label near to dressing for
documenting dressing change.
Removal Instructions
- Remove record label.
- Support the skin and catheter with finger pressure
while removing dressing
- To remove dressing, alternately stretch and release
the film section parallel to the skin to break the
adhesive bond.
Transparent I.V. Frame Dressing
(With Reinforcement)
5cm × 6cm
APPLICATION INSTRUCTIONS
1. Allow all preps and protectants to
dry thoroughly before dressing application. Peel the liner off the dressing.
2. Centre the transparent window
over the insertion site. Keep the
notched portion off the skin.
3. Press the clear part of the dressing into place ensuring securement around the catheter.
4. Slightly overlap the soft cloth tabs under the hub to form a tight seal press into place. The hub should rest on the soft cloth.
5. While slowly peeling off the paper frame,
smooth down the dressing edges. Next smooth down the dressing from the centre towards the edges, using firm pressure to enhance adhesion.
6. Use the two sterile tape strips to secure
hub, lumens and/or tubing. Fold edge of sterile tape strip over itself making a small tab for easier removal. Label dressing according to protocol.
Transparent IV. Frame Dressing
(With Reinforcement)
7cm x 8.5cm
APPLICATION INSTRUCTIONS
1. Peel open the package and remove the sterile dressing. Remove centre
cut-out.
2. Remove sterile pre-cut tape strips from centre cut-out.
3. Place the tape strips over the cannula wings for added security.
4. Peel paper liner from framed dressing, exposing adhesive surface.
5. Place dressing over cannula so that transparent film is over insertion site, Position the soft cloth tape section over the cannula wings with the port at end of deep notch. Overlap each side of the soft cloth tape underneath the port hub.
6. Remove paper frame. Smooth
dressing edges to increase adhesion.
7. Place record label near to dressing
for documenting dressing change.
REMOVAL INSTRUCTION
- Remove record label
Alternately stretch and release the film section parallel to the
skin to break the adhesive bond
Carefully peel back soft cloth tape in the direction of hair growth
Carefully peel off the soft cloth strips
To cover and protect I.V. catheter sites
Abrasions, skin tears, blisters
Skin graft donor sites
Superficial partial thickness burns
Protective eyelid coverings
Post tattoo application and removal